Starting methods of induction motor pdf

In general, the induction motor is cheaper and easier to maintain compared to other alternatives. A threephase autotransformer is used to reduce the voltage applied to the motor during the starting period. Starting of an induction motor a three phase induction motor is self starting. Starting the induction motor is the most important and dangerous step, where the motor properties play a major role in the evaluation of all electrical motors, and these properties are defined by the following. In other, starter is also provided with the motor for limiting the starting current. This starter is connected directly to the supply line, so its called directonline starter. Pdf minimization of starting torque and inrush current of. Starting of induction motor gate ee electrical machines. Induction motor starting methods brighthub engineering. You should also make a dc measurement of stator winding linetoline resistance using a dmm. The starting methods of three phase induction motor generally are directonline starting, reducedvoltage starting and soft starter.

It is well understood that induction motors draw higher currents during their starting operations than is the case under full load running conditions. Synchronous motor starting methods engineering tutorial. As induction motors are widely being used, their speed control may be required in many applications. The stator of an induction motor consists of 3phase windings, which when connected to a 3phase supply creates a rotating magnetic field. Induction motor theory jerry bednarczyk, pe course content introduction the ac induction motor is well suited to applications requiring constant speed operation. Starting methods for polyphase induction machine electrical4u. We should rotate rotor near to the speed of synchronous speed,so it attains synchronous speed. Due this high starting current motor winding is heated and have chances of insulation burning. Direct on line dol starters for less than 10 kw motors. Direct on line starter is the simplest and inexpensive methods among all other methods for starting induction motor. This final thesis will mostly be dedicated to induction motors but also to synchronous permanent magnet and reluctance motors. Methods of starting of a 3 phase induction motor the most usual methods of starting 3phase induction motors are. This is the simplest method to start the small induction motor up to 510 kilowatt. Various starting methods of induction motors are described below.

Generally an induction motor operates at almost constant speed as the load is varied. Starting methods of a single phase induction motor. Starting methods of single phase motor circuits with protection. Another technique for starting large induction motors is to reduce the voltage with an autotransformer. Starting induction motors on isolated or weak systems is a highly dynamic process that can cause motor and load damage as well as electrical network fluctuations. Reduced voltage motor starting methods include resistance starting, reactance starting, autotransformer starting, wyedelta starting, partwinding starting, and electronic soft starting. Full voltage is only applied when the motor picks up speed. There are single phase induction motors and three phase induction motors. Nov 19, 2017 in this video i explained the starting method of split phase induction motor and discuss the full operating principle of this motor. Nov 03, 2019 there are basically two types of induction motor. It directly connects the contacts of the motor to the full supply voltage.

In this method, the motor is first started as an induction motor and then starts running as a synchronous motor after achieving synchronous speed. The stator of an induction motor consists of 3phase. Starting of single phase induction motors the single phases induction motors are classified based on the method of starting method and in fact are known by the same name descriptive of the method. Here we will see a detailed article related to the starting methods of threephase induction motor. The types of induction motor depend upon the input supply. Dhawale1, anup m bhagat2, shubham e baghele 3, aishish rawada4 1prof. This is because a large amount of energy is required to magnetise the motor enough to overcome the inertia the system has at standstill. There are two types of induction motors, one with wound type rotor, also called slipring motor and another one with squirrelcage rotor. In this article we are going to discuss various methods of starting a 3 phase induction motor. In industries mostly induction motors are used for many operations.

Starting methods of synchronous motor your electrical guide. In this video i describe about the starting method of 3 phase i. For reduction in the starting current, a lower voltage is applied to the stator, especially for the squirrel cage induction motors. This is the most simple and inexpensive method of starting a squirrel cage induction motor. In this starting method of induction motor starting, torque is reduced to of starting torque obtained with direct switching. Also when we start induction motor it get high starting current. This is mainly due to the simplicity of composition, low price, light weight, high.

Technical note starting methods for ac motors reducing electrical and mechanical stress at startup the starting current of an ac motor can vary from 3 to 7 times the nominal current. For reason of economy, most houses, offices and also rural areas are supplied with single phase a. Also lets get to know the methods which are used to control the speed of squirrel cage. Jun 05, 2018 out of all the electrical machines, induction motor is the most used machine in industries. The proposed system is intended to offer soft start of the single phase induction motor using a pwm sinusoidal voltage while starting the motor. At the time of starting, the motor slip is unity, and the starting current is very large.

Starting methods of single phase motor circuits with. The discussion will be based on a matlab simulation of different loading cases of the induction motor. Dec 30, 2017 in this video, ankit goyal cofounder at kreatryx and air 1 in gate 2014 describes star delta starter method of starting induction motor. In small groups, investigate the dol starter shown. Directonline dol starters small three phase induction motors can be started directonline, which means that the rated supply is directly applied to the motor. Dhawale, priyadarshini college of engineering, nagpur, maharashtra india. Mechanical methods are impractical and, therefore the motor is started temporarily converting it into two phase motor. This method of starting is generally not convenient for large motors. Thus, it is desirable, especially for large motors, to start them at reduced voltage to keep the starting current low. The stator winding is initially connected in a star configuration and later on changed over to a delta. Simulation of 3ph induction motor in matlab with direct. The star delta starters are very suitable for delta connected motors up to 25 h. Hence, it is not advisable to start induction motors of higher ratings generally above 25kw directly from the mains supply. A advanced performances are verified through numerical methods and experiments.

In this motor, we add more turns to the auxiliary winding and we placed an electrolytic capacitor serially with the auxiliary winding. Auto transformer starting methods of induction motor. Once the motor reaches near synchronous speed, usually defined as about 95% speed, d. The star delta starter method of starting three phase induction motors is. Methods of starting three phase induction motors as we know, once a supply is connected to a three phase induction motor a rotating magnetic field will be set up in the stator, this will link and cut the rotor bars which in turn will induce rotor. As the name suggests, a starter is an electrical device which controls the electrical power for starting a motor. Analysis of different starting methods of induction motor prof. Also, a distribution law of torque reference to improve the driving characteristics of a two motor driven ev is proposed.

Record all nameplate information for the induction motor. But, as mentioned above, here, the starting current would be very large, usually 5 to 7 times the rated current. Normally with motors beyond 5 hp, starters are provided. But, as mentioned above, here, the starting current would. In the previous article we came to know that synchronous motors are not self starting so to make them start automatically we should add some tweaks.

Since the early days of induction motor availability, starting methods other than directonline have been used, and in some cases mandated by utilities, to reduce the effect of these high. This method offers easy starting and better efficiency than the earlier method. I describe different method of starting method like 1. The three ends of this winding are brought out through. Directonline starting this kind of starting mode is the most basic and simplest in the motor starting. Explain starting methods of 3 phase induction motor. We have to think about an alternative to rotate the rotor at a speed almost equal that of synchronous speed. Split phase induction motor the stator of a split phase induction motor has two windings, the main winding and the auxiliary winding. The starting and main current get split from each other by some angle, hence it gained its name split phase induction motor. As the starting current of an induction motor can be 68 times the running current the dol starter is typically only used for motors with a rating of less than 5kw. The motor is mounted in a test rig that allows one to control the torque applied to the motor shaft and to measure both rpm and torque. Starting method of split phase induction motor youtube. Induction motors draw very large currents when started at full voltage. Such high currents may pose serious problems for the motor and the electrical system when large motors are started.

Starting methods for polyphase induction machine february 17, 2019 february 24, 2012 by electrical4u in this article we are going to discuss various methods of starting a 3 phase induction motor. The above method of starting synchronous motor as a squirrel cage induction motor does not provide high starting torque. But starting current would be very large, up to 5 to 7 times of rated current. In this video, ankit goyal cofounder at kreatryx and air 1 in gate 2014 describes star delta starter method of starting induction motor. This paper describes a method to improve the control characteristics of an interior permanent magnet synchronous motor for an electric vehicle. Induction motors protection and starting by viv cohen. The comparison of starting torque with star and delta.

In this method, the starter is connected directly to supply voltage. There are two basic reasons for the use of singlephase motors rather than 3phase motors. Mar 16, 2016 in the previous article we came to know that synchronous motors are not self starting so to make them start automatically we should add some tweaks. The starting current is very large, normally 6 to 8 times the rated current. The electric motor and connected load accelerates to the rated speed from rest under the influence of the starting torque. Starting synchronous motors powell industries, inc.

By far the most commonly used ac motor is the induction motor. Starting methods of three phase induction motor electrical. Mostly in conveyer, when induction motor is starts it experiences jerk. Starting a synchronous motor using damper windings. When started as an induction motor, the methods of starting are the same as for induction motors, i. In this method rated supply voltage is directly applied to the motor. More than 90% of motors used in industries are squirrel cage induction motor due to its rugged and maintenance free design. Mohammed azher therib starting method for induction motors a 3phase induction motor is theoretically self starting. An induction motor has the ability to self start owing to the interaction between the rotating magnetic field flux and the rotor winding.

A squirrel cage induction motor therefore draws a very high starting. Now let us have a brief recall of the need for having a starter for any motor. P auto transformer starting methods of induction motor. As discussed in earlier post revolving field theory of single phase induction motors, a single phase induction motor with main stator winding alone has no inherent starting torque as the main stator winding only produces stationary pulsating air gap flux wave. A comparison of induction motor starting methods being. After looking at some of the considerations for fullvoltage starting, we will consider several. May 18, 2018 as discussed in earlier post revolving field theory of single phase induction motors, a single phase induction motor with main stator winding alone has no inherent starting torque as the main stator winding only produces stationary pulsating air gap flux wave. This system avoids the frequently used triacphaseangle control drives and provides variable ac voltage during the starting of the single phase induction motor.

Different speed control methods of induction motor are explained below. The following are the different methods to start a synchronous motor. In this method, a small induction motor known as pony motor is used to bring the motor speed to synchronous speed. We have some fine methods to start the synchronous motor. Since a synchronous motor is inherently not self starting, the following starting methods of synchronous motor are adopted generally starting methods of synchronous motor. The induction motor model is created according to a group of standard equations. The taps on the autotransformer can be adjusted offering the choice of several different levels of voltage reduction. Starting of squirrel cage induction motors485 an induction motor can be regarded as a transformer with a small air gap in the magnetic circuit. Induction motors are considered nowadays the most commonly used electrical machines, which are mainly used as electrical induction motors and sometimes as generators. So to achieve this, instead of shorting the damper winding, it is designed to a form a three phase star or delta connected winding.

Single phase induction motors,and their starting methods. Transient processes involved with the starting method of induction motor in a variable speed drive require a detailed study. A 3 phase induction motor can be used for different applications with various speed and load requirements. By this method small motors up to 5 kw rating is started to avoid the supply voltage fluctuation. Pdf minimization of starting torque and inrush current. Threephase induction motors draw six or more times rated current when started at rated voltage. A comparison of induction motor starting methods being powered by a dieselgenerator set adam wigington, m. A 3phase induction motor is theoretically self starting.

When the supply is connected to the stator of a threephase induction motor, a rotating magnetic field is produced, and the rotor starts rotating and the induction motor starts. Before we discuss this, it is very essential here to recall the torque slip characteristic of the three phase induction motor which is given below. At the starting of the motor both components of magnetic flux will be equal in magnitude and oppose each other so they will cancel each other, hence the net torque will be zero and thats the reason which makes single phase induction motor, not selfstarting motors. Starting of an induction motor starting methods circuit globe. This will link and cut the rotor conductors which in turn will induce a current in the rotor conductors and. The initial starting current is large, normally about 5 to 7 times the rated current but the starting torque is likely to be 0. An induction motor or asynchronous motor is an ac electric motor in which the electric current in the rotor needed to produce torque is obtained by electromagnetic induction from the magnetic field of the stator winding. Dol starter is connected directly between the supply and motor terminal. A soft starter is any device which controls the acceleration of an electric motor by means of controlling the applied voltage. For effective starting of induction motor different methods are used. Starting methods of a single phase induction motor circuit. So this can be possible by employing various methods to start the synchronous motor. For the development of starting torque, rotating field at the starting must be produced.

Starting method of induction motor energy relations. The motor is switched on directly to full supply voltage. The induction motor is made up of the stator, or stationary windings, and the rotor. Starting methods of a single phase induction motor the single phase motor is not self starting and hence needs an auxiliary means or equipment to start the single phase induction motor. Read more methods of speed control of induction motor. What is generally not recognised, is the existence of short duration inrush currents, that greatly exceed these. An induction motor can therefore be made without electrical connections to the rotor. For squirrelcage motors directon line starting stardelta starting autotransformer starting. At the motor for electric vehicle, d and qaxis inductances are varied to a great extent.

Simulation of 3ph induction motor in matlab with direct and. Sep 30, 2015 starting method for 3 phase induction motor 1. The method is characterized by less investment, simple equipment and small quantity. Know how the speed control is easily achieved by changing the number of stator poles. Introduction motor starters are one of the major inventions for motor control applications. One way to reduce the starting current is to start the motor at reduced voltage. The transient operation during is satisfactory if a. Reduced voltage motor starters electrical academia. Three phase induction motor or ac motor is started by itself but we require some starter or other methods for proper starting and controlling induction motor. Starting method for induction motors a 3phase induction motor is theoretically self starting.